TUFLOW Message 3027: Difference between revisions

Content deleted Content added
No edit summary
No edit summary
Line 1:
{{TUFLOW_Message
|tuflow_message=ERROR 3027: - Roughness height specified but nLim less than 0.
<br>
|alt_msg=NoneNA<br>
 
|type=[[ERROR]]
|message_desc=Materials may use use either fixed mannings, depth-varying mannings, or log-law roughness formulations for bed resistance.
|message_desc=The limiting Manning’s n value, required for specifying bed resistance with the theoretically derived log law for shallow flows, must be greater than or equal to 0.0.
When utilising log-law roughness, a maximum limit for equivalent mannings number is required as the formulation becomes singular at shallow depths.
|suggestions=A limiting Manning’s n value (based on the n value that would normally be applied) is specified to transition to conventional n values at greater depths.
This limit, provided as the fixed mannings n value in the material data, must be greater than zero.
|suggestions=Ensure that all materials that utilise log-law roughness have positive values for mannings n.
 
|prelink=[[TUFLOW_Message_3026|Message 3026]]