TUFLOW Message 1093: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{TUFLOW_Message |
{{TUFLOW_Message |
||
|tuflow_message=ERROR 1093 - No entry width provided for pit type ",a,". |
|tuflow_message=ERROR 1093 - No entry width provided for pit type ",a,". |
||
|alt_msg=ERROR 1093 - Entry width provided for pit type or yQ curve " |
|alt_msg=ERROR 1093 - Entry width provided for pit type or yQ curve "b" is less than or equal to zero. |
||
|type=[[ERROR]]<br> |
|type=[[ERROR]]<br> |
||
[[WARNING]] |
[[WARNING]] |
Revision as of 13:36, 16 August 2022
TUFLOW Message
ERROR 1093 - No entry width provided for pit type ",a,".
Alternate Message
ERROR 1093 - Entry width provided for pit type or yQ curve "b" is less than or equal to zero.
Description
Caused when a null or less than or equal to zero width for Q pits is encountered. This message is outputted for the TUFLOW 2012-05 release and prevents TUFLOW from crashing or for NaNs to appear. If Defaults == Pre-2012 is set, a WARNING 1093 is issued and the model simulation will not stop.
Suggestions
Check for a null or less than or equal to zero width within a Q pit.
Up |
---|
![]() |