Revision as of 15:11, 22 December 2022
TUFLOW Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary upstream channel "b".
Alternate Message
WARNING 1100 - Structure "a" crest/invert is below bed of primary downstream channel "b".
Message Type
WARNING
Description
The WARNING is issued where a 1D structure’s invert/bed lies below the invert/bed of the primary upstream and/or downstream channel.
Suggestions
For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.