TUFLOW Message 1025: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
Line 3:
|alt_msg=ERROR 1025 - Number of culvert channels and CV details not the same. <br> ERROR 1025 - Number of variable geometry channels and VG tables not the same. <br> ERROR 1025 - Number of weir channels and WR details not the same.
|type=[[ERROR]]
|message_desc=Bridge structures are modelled using a height varying form loss coefficient rather than fixed contraction and expansion losses. A table (referred to as a BG Table) of backwater or form loss coefficient versus height is required for each bridge channel. BG Tables can be entered using .csv files via a 1d_tab (often renamed as 1d_bg) layer (see
Where the loss coefficient is constant through to the bridge deck (eg. no losses such as a clear spanning bridge, or pier losses only), the BG table can automatically be created by specifying a positive non-zero value for the Form_or_Bend_Loss attribute in the 1d_nwk layer (see
As of 2010 TUFLOW build, fixed field format inputs are no longer supported. Prior to build 2010, these losses could be applied in fixed field format.
|suggestions=Ensure that each bridge channel has a BG table specified either via a 1d_tab layer, or via a fixed coefficient in the 1d_nwk layer. Check that fixed field losses are not being used, as these may be ignored in later versions of TUFLOW.
| |||