{{TUFLOW_Message
{{TUFLOW_Message
|tuflow_message=ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>
|tuflow_message=ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>.
|alt_msg=N/A
|alt_msg=N/A
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
|message_desc=Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
|suggestions=Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.<br>
Please contact [mailto:support@tuflow.com support@tuflow.com].


|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]]

Revision as of 16:38, 23 February 2023

TUFLOW Message
ERROR 1423 - Virtual Pit occurs at the same location as a user defined node, manhole or a pit IDs: <channel ids>.

Alternate Message
N/A

Message Type
ERROR

Description
Virtual Pit outlet cannot be connected to the same location as a user defined node, manhole or a pit.

Suggestions
Consider connection by upstream or downstream end of the channel instead. Virtual pits need to be read in before 1d_nwk if they are discharging into 1D channels.
Please contact support@tuflow.com.


Up
1xxx Messages