Difference between revisions of "TUFLOW Message 2386"
Line 1: | Line 1: | ||
{{TUFLOW_Message | {{TUFLOW_Message | ||
|tuflow_message=WARNING 2386 - Output data type "dt" not valid for Classic solution scheme. | |tuflow_message=WARNING 2386 - Output data type "dt" not valid for Classic solution scheme. | ||
− | |alt_msg=WARNING 2386 - | + | |alt_msg=WARNING 2386 - Output data type "Nu" not valid for Classic solution scheme. Please use "Cr" instead.<br> |
− | WARNING 2386 - | + | WARNING 2386 - Output data type "Nc" not valid for Classic solution scheme. Please use "Cr" instead.<br> |
− | WARNING 2386 - | + | WARNING 2386 - Output data type "Nd" not valid for Classic solution scheme. Please use "Cr" instead.<br> |
− | WARNING 2386 - | + | WARNING 2386 - Output data type "Cr" not valid for HPC solution scheme. Please use "Nu", "Nc", or "Nd" instead.<br> |
+ | WARNING 2386 - Output data type "CI" not valid with horizontal sub-surface flows or multiple vertical soils layers.<br> | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
|message_desc=TUFLOW Classic solver applies fixed timestep and do not support the output data type "dt", "Nu", "Nc", or "Nd" (the <u>[[HPC_Adaptive_Timestepping | HPC adaptive timestepping]]</u>). On the other hand, "Cr" is the Courant Number output in TUFLOW Classic solution scheme, and it is not supported by TUFLOW HPC solver. | |message_desc=TUFLOW Classic solver applies fixed timestep and do not support the output data type "dt", "Nu", "Nc", or "Nd" (the <u>[[HPC_Adaptive_Timestepping | HPC adaptive timestepping]]</u>). On the other hand, "Cr" is the Courant Number output in TUFLOW Classic solution scheme, and it is not supported by TUFLOW HPC solver. |
Revision as of 19:14, 9 March 2023
TUFLOW Message
WARNING 2386 - Output data type "dt" not valid for Classic solution scheme.
Alternate Message
WARNING 2386 - Output data type "Nu" not valid for Classic solution scheme. Please use "Cr" instead.
WARNING 2386 - Output data type "Nc" not valid for Classic solution scheme. Please use "Cr" instead.
WARNING 2386 - Output data type "Nd" not valid for Classic solution scheme. Please use "Cr" instead.
WARNING 2386 - Output data type "Cr" not valid for HPC solution scheme. Please use "Nu", "Nc", or "Nd" instead.
WARNING 2386 - Output data type "CI" not valid with horizontal sub-surface flows or multiple vertical soils layers.
Message Type
WARNING
Description
TUFLOW Classic solver applies fixed timestep and do not support the output data type "dt", "Nu", "Nc", or "Nd" (the HPC adaptive timestepping). On the other hand, "Cr" is the Courant Number output in TUFLOW Classic solution scheme, and it is not supported by TUFLOW HPC solver.
Suggestions
Use supported output data types in each solver.