|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=This error is triggered when TUFLOW did not correctly read the 2d_po or 2d_lp GIS layer attribute data. This is commonly caused by the incorrect data types or incorrect number of attributes. |
− | |suggestions= | + | |suggestions=Double check the GIS layer attributes for the 2d_po/2d_lp that is causing the issue. Check the attribute type and number of attributes against the equivalent empty type or compare against what is listed in the TUFLOW User Manual. |
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | |uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]] | ||
}} | }} |
Revision as of 00:42, 28 May 2025
TUFLOW Message
ERROR 2823 - Reading PO / RL attribute data.
Alternate Message
ERROR 2823 - Reading LP attribute data.
Message Type
ERROR
Description
This error is triggered when TUFLOW did not correctly read the 2d_po or 2d_lp GIS layer attribute data. This is commonly caused by the incorrect data types or incorrect number of attributes.
Suggestions
Double check the GIS layer attributes for the 2d_po/2d_lp that is causing the issue. Check the attribute type and number of attributes against the equivalent empty type or compare against what is listed in the TUFLOW User Manual.