Difference between revisions of "TUFLOW Message 1118"
Line 3: | Line 3: | ||
|alt_msg=ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database. | |alt_msg=ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database. | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples | + | |message_desc=For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples, refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u>. |
|suggestions=Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified. | |suggestions=Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified. | ||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | |uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] | ||
}} | }} |
Latest revision as of 09:52, 23 September 2024
TUFLOW Message
ERROR 1118 - Could not find pit inlet type ",a," in the pit inlet database.
Alternate Message
ERROR 1118 - Could not find y-Q curve ",a," for P or Q channel ",a," in the Depth Discharge Database. Check that it exists in the Pit Inlet or Depth Discharge database.
Message Type
ERROR
Description
For a "Q" type pit channel a depth-discharge relationship must be specified. A pit inlet type is specified via the 1d_nwk attribute Inlet_Type. For each inlet type there must be an entry in the Pit Inlet Database, which links to the depth-discharge relationship. For more information and examples, refer to the TUFLOW Manual.
Suggestions
Ensure that the correct inlet type has been specified in the 1d_nwk and that an entry in the Pit Inlet Database exists for inlet type specified.
Up |
---|