Line 10: Line 10:
 
:* Input BC Connection Layers: If available, select the 2d_bc connection layer (i.e. '''1D2D_Urban_001_2d_bc_L''').
 
:* Input BC Connection Layers: If available, select the 2d_bc connection layer (i.e. '''1D2D_Urban_001_2d_bc_L''').
 
:* General Options:  
 
:* General Options:  
:::* Maximum Depth Option (Ymax): 'Set to 0.0'.
+
:::* Maximum Depth Option (Ymax): Leave as is
:::* Nodes receiving subcatchment flows option (if connected to 2D): 'Set Apond = 0.0; Ksur = 0.0 (overwrites options below)'.
+
:::* Nodes receiving subcatchment flows option (if connected to 2D): Based on Options Below
:* Nodes connected to 2D without Inlets:
+
:* Nodes connected to 2D without Inlets (through embankment culvert):
 
:::* Ysur: 0
 
:::* Ysur: 0
 
:::* Area of ponding: This value should match the 2D cell area associated with 1D/2D culvert connections.
 
:::* Area of ponding: This value should match the 2D cell area associated with 1D/2D culvert connections.
:* Nodes connected to 2D with Inlets:
+
:* Nodes connected to 2D with Inlets (underground pipe network):
 
:::* Maximum depth (Ymax) option: 'Use global option'
 
:::* Maximum depth (Ymax) option: 'Use global option'
 
:::* Ysur: 0
 
:::* Ysur: 0
 
:::* Area of ponding: This value should match the 2D cell area associated with the Inlet Usage connections.
 
:::* Area of ponding: This value should match the 2D cell area associated with the Inlet Usage connections.
:* Nodes without 2D Connection:
+
:* Nodes without 2D Connection (underground pipe network):
 
:::* Surcharge Depth: This value should be a value higher than any expected water level in the model.
 
:::* Surcharge Depth: This value should be a value higher than any expected water level in the model.
 
:::* Area of ponding: 1
 
:::* Area of ponding: 1
 +
 
<li>Select 'Modify All Features'. Once the tool has finished, click 'Close'.
 
<li>Select 'Modify All Features'. Once the tool has finished, click 'Close'.
 
<li>Turn off editing to save the edits.
 
<li>Turn off editing to save the edits.

Revision as of 10:44, 16 February 2024

Update SWMM Nodes--Junctions Attributes

The following GIS feature updates to the Nodes--Junctions attributes will finalize the SWMM portion of the TUFLOW model. This is typically the final step in the model building process, as the recommended attributes for junction node vary depending on whether the node is associated with inlet usage connections, 1D/2D culvert connections and SWMM hydrology sub-catchments.

  1. In the QGIS Layers panel, select (left click) Nodes--Junctions and toggle on editing.
  2. In the Processing Toolbox, select the 'Edit Features In-Place' tool. This allows the editing of an existing layer, instead of the creation of a new layer.
  3. Go to TUFLOW >> SWMM in the processing tool list and select the 'Junctions - Set attributes ' processing tool. This opens the dialog shown below.
    • Input Subcatchment layers: If available, select Hydrology--Subcatchments.
    • Input Inlet Usage Layers: If available, select the inlet usage layer (i.e. swmm_iu_XP_001)
    • Input BC Connection Layers: If available, select the 2d_bc connection layer (i.e. 1D2D_Urban_001_2d_bc_L).
    • General Options:
    • Maximum Depth Option (Ymax): Leave as is
    • Nodes receiving subcatchment flows option (if connected to 2D): Based on Options Below
    • Nodes connected to 2D without Inlets (through embankment culvert):
    • Ysur: 0
    • Area of ponding: This value should match the 2D cell area associated with 1D/2D culvert connections.
    • Nodes connected to 2D with Inlets (underground pipe network):
    • Maximum depth (Ymax) option: 'Use global option'
    • Ysur: 0
    • Area of ponding: This value should match the 2D cell area associated with the Inlet Usage connections.
    • Nodes without 2D Connection (underground pipe network):
    • Surcharge Depth: This value should be a value higher than any expected water level in the model.
    • Area of ponding: 1
  4. Select 'Modify All Features'. Once the tool has finished, click 'Close'.
  5. Turn off editing to save the edits.
  6. View the attributes within Nodes--Junctions to verify the data processing has been completed correctly.
    For a summary of the attributes associated with the Nodes--Junctions layer, refer to TUFLOW 2023-03-AD Release Notes (Table A.30) and the SWMM Reference Manual - Volume 2 (Hydraulics).



Up
Go-up.png Back to XPSWMM to TUFLOW Conversion Page