TUFLOW Message 2011: Difference between revisions
No edit summary |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=A .tgc materials command such as "Set Mat ==", "Read GIS Mat ==", "Read RowCol Mat ==" or "Read RowCol Grid ==" has been specified, but "Read Materials File ==" in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used. <br> |
|message_desc=A .tgc materials command such as "<font color="blue"><tt>Set Mat </tt></font><font color="red"><tt>==</tt></font>", "<font color="blue"><tt>Read GIS Mat </tt></font><font color="red"><tt>==</tt></font>", "<font color="blue"><tt>Read RowCol Mat </tt></font><font color="red"><tt>==</tt></font>" or "<font color="blue"><tt>Read RowCol Grid </tt></font><font color="red"><tt>==</tt></font>" has been specified, but "<font color="blue"><tt>Read Materials File </tt></font><font color="red"><tt>==</tt></font>" in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used. <br> |
||
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br> |
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.<br> |
||
|suggestions=Check that your <u>'''.tcf'''</u> (not .tgc) file contains a "Read Materials File == " command. |
|suggestions=Check that your <u>'''.tcf'''</u> (not .tgc) file contains a "<font color="blue"><tt>Read Materials File </tt></font><font color="red"><tt>==</tt></font> " command. |
||
|discussion_page=* [[Talk:TUFLOW Message 2010|Discuss Message 2010]] |
|discussion_page=* [[Talk:TUFLOW Message 2010|Discuss Message 2010]] |
||
|link3='' |
|link3='' |
||
Revision as of 08:59, 24 June 2022
TUFLOW Message
ERROR 2011 - Using Mat command when no materials file has been specified.
Alternate Message
NA
Message Type
ERROR
Description
A .tgc materials command such as "Set Mat ==", "Read GIS Mat ==", "Read RowCol Mat ==" or "Read RowCol Grid ==" has been specified, but "Read Materials File ==" in the .tcf file has not been specified. A materials file must be specified if .tgc Mat commands are used.
This ERROR was introduced in Build 2010-10-AC. Prior to Build 2010-10-AC, if no materials file was specified a default Manning's n value of 0.05 is used. The 2d_uvpt_check layer can be used to validate the Manning's n values assigned to the model after all inputs.
Suggestions
Check that your .tcf (not .tgc) file contains a "Read Materials File == " command.
| Up |
|---|