Line 7: | Line 7: | ||
[[CHECK]] | [[CHECK]] | ||
|message_desc=A cell side encountered overlapping flow constrictions. | |message_desc=A cell side encountered overlapping flow constrictions. | ||
− | |suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions | + | |suggestions=From 2023 release, overlapping flow constriction triggers an error.<br> Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions. |
Latest revision as of 09:36, 5 August 2025
TUFLOW Message
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZV point.
Alternate Message
ERROR 2467 - Overlapping Layered Flow Constriction Shape at ZU point.
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZV point.
CHECK 2467 - Layered Flow Constriction Shape overlaps with Flow Constriction Shape at ZU point.
Description
A cell side encountered overlapping flow constrictions.
Suggestions
From 2023 release, overlapping flow constriction triggers an error.
Modify the flow constriction shapes to avoid overlapping. If the overlap is intentional, use a different flow constriction combining parameters from the original flow constrictions.