TUFLOW Message 2835: Difference between revisions
Content deleted Content added
No edit summary |
No edit summary |
||
Line 6:
|type=[[ERROR]]
|message_desc=Not expecting point / line / region for BC type: "<>". A point / line / region is not valid for the boundary condition (BC) type "<>".
<br>
|suggestions=Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for information on the BC type "<>" and its specifications. ▼
From the 2023-03 release, a point-type QT boundary is not supported when using Quadtree.
▲|suggestions=*Refer to the <u>[https://docs.tuflow.com/classic-hpc/manual/latest/ TUFLOW Manual]</u> for information on the BC type "<>" and its specifications.
*If a QT point was used as an internal inflow boundary before the 2023-03 release, transitioning to a 2d_sa setup is recommended. For an external boundary, the preferred approach is to use a 2d_bc QT line snapped to the code polygon.
|uplink=[[2xxx_TUFLOW_Messages|2xxx Messages]]
| |||