TUFLOW Message 6009: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 6: | Line 6: | ||
|message_desc=SX connections are only valid at outfall nodes or standalone nodes to convey subcatchment flows to a 2D domain. |
|message_desc=SX connections are only valid at outfall nodes or standalone nodes to convey subcatchment flows to a 2D domain. |
||
|suggestions= |
|suggestions=Review the SX connection. |
||
|uplink=[[6xxx_TUFLOW_Messages|6xxx Messages]] |
|uplink=[[6xxx_TUFLOW_Messages|6xxx Messages]] |
||
Latest revision as of 01:30, 14 December 2024
TUFLOW Message
ERROR 6009 Improper SX Connection. Inlets must be connected at Junctions not Outfalls for SWMM node: <a>.
Alternate Message
ERROR 6009 Improper SX Connection. Non-inlet SX connections can only be assigned to outfalls and stand alone nodes. Change to HX connection, add inlet, or change to outfall node. SWMM node: <a>
Message Type
ERROR
Description
SX connections are only valid at outfall nodes or standalone nodes to convey subcatchment flows to a 2D domain.
Suggestions
Review the SX connection.