|type=[[ERROR]]
|message_desc=Cross-Sectional data for the channel named "XXXX" cannot be found.
|suggestions=Each channel requires a table describing its hydraulic properties to define its conveyance. The properties are normally defined by digitising a cross-section in a 1d_xs or 1d_tab layer positioned midway along the channel or at the channel ends. If the cross-section is applied at channel ends, only applicable to open channels, circular and rectangular culverts, the cross-section lines must have a mid-vertex snapped to the channel end. If the cross-section is positioned midway along the channel, applicable to all 1D structures, it must have either:
* Only two vertices crossing the 1D network.