Difference between revisions of "TUFLOW Message 1037"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=CHECK 1037 - Channel ",a," interpolated from XS ",a," (",a,"%) and XS ",a," (",a,"%). |alt_msg=NA |type=CHECK |message_desc=???? |suggestions...')
 
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=CHECK 1037 - Channel ",a," interpolated from XS ",a," (",a,"%) and XS ",a," (",a,"%).
+
|tuflow_message=CHECK 1037 - Channel <channel ID> interpolated from XS <cross-section 1> (<weighting for cross-section 1> as %) and XS <cross-section 2> (<weighting for cross-section 2> as %).
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[CHECK]]
 
|type=[[CHECK]]
|message_desc=????
+
|message_desc=A channel cross-section has not been specified, cross-sectional properties interpolated from upstream and downstream cross-sections listed. Weighting for interpolation are listed.<br>
|suggestions=????
+
 
 +
Cross section interpolation can be globally turned off, forcing each channel to have a cross-section specified.  This is done with the .ecf command: <font color="green"><tt>Interpolate Cross-Sections == OFF</tt></font>.
 +
|suggestions=Check if interpolatted cross-section is desired in this location.<br>
 +
 
 +
Interpolated cross-section properties can be found in <''runfile_''1d_ta_tables_check.csv> which is written with the 1D check files location as specified with the .ecf command <font color="green"><tt>Write Check Files == <location></tt></font>
 
|discussion_page=* [[Talk:TUFLOW Message 1037|Discuss Message 1037]]
 
|discussion_page=* [[Talk:TUFLOW Message 1037|Discuss Message 1037]]
 
|link3=''
 
|link3=''

Revision as of 17:38, 6 February 2011

TUFLOW Message
CHECK 1037 - Channel <channel ID> interpolated from XS <cross-section 1> (<weighting for cross-section 1> as %) and XS <cross-section 2> (<weighting for cross-section 2> as %).

Alternate Message
NA

Message Type
CHECK

Description
A channel cross-section has not been specified, cross-sectional properties interpolated from upstream and downstream cross-sections listed. Weighting for interpolation are listed.

Cross section interpolation can be globally turned off, forcing each channel to have a cross-section specified. This is done with the .ecf command: Interpolate Cross-Sections == OFF.

Suggestions
Check if interpolatted cross-section is desired in this location.

Interpolated cross-section properties can be found in <runfile_1d_ta_tables_check.csv> which is written with the 1D check files location as specified with the .ecf command Write Check Files == <location>


Up
Go-up.png 1xxx Messages