Difference between revisions of "TUFLOW Message 1061"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1061 - Data in table incomplete for flag: ",a, |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |discussion_page=* [[Talk:T...')
 
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=A flag has been specified for an XZ, CS or HW table within a 1d_tab GIS layer. The data expected for this flag is incomplete from the source csv file. This message may also occur with [[TUFLOW Message 1063|ERROR 1063]] if data is missing altogether from the source csv file.
|suggestions=????
+
|suggestions=Open the source csv file and ensure data has been populated for all rows within the table. Also ensure the data has been entered within the correct column of the source csv file, noting that this differs depending on the table type and flag. <br>
 +
For example, relative resistance (R, M or N) values for an XZ table are entered in Column 3 of the source csv file. For an HW table, vertical resistance (F or N) is entered in Column 5 of the source csv file. Refer to Table 4.17 of the 2010 TUFLOW Manual for further information.
 +
 
 
|discussion_page=* [[Talk:TUFLOW Message 1061|Discuss Message 1061]]
 
|discussion_page=* [[Talk:TUFLOW Message 1061|Discuss Message 1061]]
 
|link3=''
 
|link3=''

Revision as of 00:40, 13 January 2016

TUFLOW Message
ERROR 1061 - Data in table incomplete for flag: ",a,

Alternate Message
NA

Message Type
ERROR

Description
A flag has been specified for an XZ, CS or HW table within a 1d_tab GIS layer. The data expected for this flag is incomplete from the source csv file. This message may also occur with ERROR 1063 if data is missing altogether from the source csv file.

Suggestions
Open the source csv file and ensure data has been populated for all rows within the table. Also ensure the data has been entered within the correct column of the source csv file, noting that this differs depending on the table type and flag.
For example, relative resistance (R, M or N) values for an XZ table are entered in Column 3 of the source csv file. For an HW table, vertical resistance (F or N) is entered in Column 5 of the source csv file. Refer to Table 4.17 of the 2010 TUFLOW Manual for further information.


Up
Go-up.png 1xxx Messages