− | |message_desc= | + | |message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the bed of the primary upstream and/or downstream channel. |
− | |suggestions= | + | |suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results. |
|discussion_page=* [[Talk:TUFLOW Message 1100|Discuss Message 1100]] | |discussion_page=* [[Talk:TUFLOW Message 1100|Discuss Message 1100]] | ||
|link3='' | |link3='' |
Revision as of 16:20, 3 October 2014
TUFLOW Message
WARNING 1100 - ????
Alternate Message
N/A
Message Type
WARNING
Description
The WARNING is issued where a 1D structure’s invert/bed lies below the bed of the primary upstream and/or downstream channel.
Suggestions
For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.