|message_desc=????
+
|message_desc=The WARNING is issued where a 1D structure’s invert/bed lies below the bed of the primary upstream and/or downstream channel.
|suggestions=????
+
|suggestions= For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.
 