Difference between revisions of "TUFLOW Message 1100"

From Tuflow
Jump to navigation Jump to search
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
|tuflow_message=WARNING 1100 - ????
+
|tuflow_message=WARNING 1100 - Structure crest/invert is below bed of primary upstream channel
 
|alt_msg= N/A
 
|alt_msg= N/A
 
|type=[[WARNING]]
 
|type=[[WARNING]]

Revision as of 16:58, 21 August 2018

TUFLOW Message
WARNING 1100 - Structure crest/invert is below bed of primary upstream channel

Alternate Message
N/A

Message Type
WARNING

Description
The WARNING is issued where a 1D structure’s invert/bed lies below the bed of the primary upstream and/or downstream channel.

Suggestions
For Build 2013-12-AB onwards, if this WARNING is issued, a review of the 1D topography and structure invert/dimensions is recommended. For Build 2013-12-AA, the issuing of this warning is incorrect and has no effect on the results.


Up
Go-up.png 1xxx Messages