Difference between revisions of "TUFLOW Message 1154"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=CHECK 1154 - For channel ",a,", no upstream end cross-section specified (using downstream end cross-section). |alt_msg=NA |type=CHECK |messag...') |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[CHECK]] | |type=[[CHECK]] | ||
− | |message_desc= | + | |message_desc=A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel. |
− | |suggestions= | + | |suggestions=Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section. |
|discussion_page=* [[Talk:TUFLOW Message 1154|Discuss Message 1154]] | |discussion_page=* [[Talk:TUFLOW Message 1154|Discuss Message 1154]] | ||
|link3='' | |link3='' |
Revision as of 14:44, 1 February 2011
TUFLOW Message
CHECK 1154 - For channel ",a,", no upstream end cross-section specified (using downstream end cross-section).
Alternate Message
NA
Message Type
CHECK
Description
A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel.
Suggestions
Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section.
Up |
---|