Difference between revisions of "TUFLOW Message 1154"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=CHECK 1154 - For channel ",a,", no upstream end cross-section specified (using downstream end cross-section). |alt_msg=NA |type=CHECK |messag...')
 
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[CHECK]]
 
|type=[[CHECK]]
|message_desc=????
+
|message_desc=A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel.
|suggestions=????
+
|suggestions=Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section.
 
|discussion_page=* [[Talk:TUFLOW Message 1154|Discuss Message 1154]]
 
|discussion_page=* [[Talk:TUFLOW Message 1154|Discuss Message 1154]]
 
|link3=''
 
|link3=''

Revision as of 14:44, 1 February 2011

TUFLOW Message
CHECK 1154 - For channel ",a,", no upstream end cross-section specified (using downstream end cross-section).

Alternate Message
NA

Message Type
CHECK

Description
A downstream end cross-section is specified, but no upstream end cross-section is specified. This may result in a 0 gradient channel.

Suggestions
Specify a upstream end cross-section, or ensure that inverts are appropriate if using only a downstream end cross-section.


Up
Go-up.png 1xxx Messages