Difference between revisions of "TUFLOW Message 1203"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |di...') |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:<br> |
− | |suggestions= | + | *SX<br> |
+ | *SXL<br> | ||
+ | *SXZ<br> | ||
+ | *SXG<br> | ||
+ | *SXS<br> | ||
+ | For a detalied description of these options see Section 4.5.1.3 (Connecting Pits and Nodes to 2D Domains) and Table 4.14 (1D model Network (1d_nwk) Attribute Descriptions) of the TUFLOW manual (2010 version). | ||
+ | |suggestions=Specify a valid attribute as per the list above. | ||
|discussion_page=* [[Talk:TUFLOW Message 1203|Discuss Message 1203]] | |discussion_page=* [[Talk:TUFLOW Message 1203|Discuss Message 1203]] | ||
|link3='' | |link3='' |
Revision as of 15:28, 1 February 2011
TUFLOW Message
ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters.
Alternate Message
NA
Message Type
ERROR
Description
An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:
- SX
- SXL
- SXZ
- SXG
- SXS
For a detalied description of these options see Section 4.5.1.3 (Connecting Pits and Nodes to 2D Domains) and Table 4.14 (1D model Network (1d_nwk) Attribute Descriptions) of the TUFLOW manual (2010 version).
Suggestions
Specify a valid attribute as per the list above.
Up |
---|
1xxx Messages |