Difference between revisions of "TUFLOW Message 1256"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1256 - Cannot use the interpolate cross-sections feature with fixed field input. |alt_msg=NA |type=ERROR |message_desc=???? |suggestion...')
 
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=Cross-section interpolation is not compatible with fixed field formatted input.
|suggestions=????
+
|suggestions=Either convert fixed field data to tabular (.csv) format data, or turn off cross section interpolation with the ecf command (<tt>Interpolate Cross-Sections == OFF</tt>).
 
|discussion_page=* [[Talk:TUFLOW Message 1256|Discuss Message 1256]]
 
|discussion_page=* [[Talk:TUFLOW Message 1256|Discuss Message 1256]]
 
|link3=''
 
|link3=''

Revision as of 09:14, 2 February 2011

TUFLOW Message
ERROR 1256 - Cannot use the interpolate cross-sections feature with fixed field input.

Alternate Message
NA

Message Type
ERROR

Description
Cross-section interpolation is not compatible with fixed field formatted input.

Suggestions
Either convert fixed field data to tabular (.csv) format data, or turn off cross section interpolation with the ecf command (Interpolate Cross-Sections == OFF).


Up