− | |message_desc= | + | |message_desc=The 1D restart file (.erf) has encountered and end of file error whilst reading. The most likely cause for this is that the 1D network has changed between the model simulation and the model in which the restart file was written. |
− | |suggestions= | + | |suggestions=If the 1D netwrok has been changed starting from a restart file is not possible and a new restart file needs to be created. |
|discussion_page=* [[Talk:TUFLOW Message 1266|Discuss Message 1266]] | |discussion_page=* [[Talk:TUFLOW Message 1266|Discuss Message 1266]] | ||
|link3='' | |link3='' |
Revision as of 09:43, 2 February 2011
TUFLOW Message
ERROR 1266 - Error or end of file whilst reading .erf file. 1D network has most likely changed.
Alternate Message
NA
Message Type
ERROR
Description
The 1D restart file (.erf) has encountered and end of file error whilst reading. The most likely cause for this is that the 1D network has changed between the model simulation and the model in which the restart file was written.
Suggestions
If the 1D netwrok has been changed starting from a restart file is not possible and a new restart file needs to be created.