TUFLOW Message 2030: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 4: Line 4:
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
|suggestions=Seperate incompatible boundary types, for example a single 2D cell cannot be both a water level boudary and a flow boundary.
|suggestions=????
|discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]]
|discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]]
|link3=''
|link3=''

Revision as of 16:49, 6 February 2011

TUFLOW Message
ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary.

Alternate Message
NA

Message Type
ERROR

Description
Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).

Suggestions
Seperate incompatible boundary types, for example a single 2D cell cannot be both a water level boudary and a flow boundary.


Up
2xxx Messages