|tuflow_message=ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit. | |tuflow_message=ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit. | ||
− | |alt_msg= | + | |alt_msg=ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units. |
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit | + | |message_desc=2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model. |
− | |suggestions= | + | |suggestions= Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units. |
|discussion_page=* [[Talk:TUFLOW Message 2043|Discuss Message 2043]] | |discussion_page=* [[Talk:TUFLOW Message 2043|Discuss Message 2043]] | ||
|link3='' | |link3='' |
Revision as of 12:19, 19 January 2015
TUFLOW Message
ERROR 2043 - 2D HX cell has been assigned to an ISIS non-RIVER unit.
Alternate Message
ERROR 2043 - Flow from 2D HX cell has been assigned to an ISIS non-RIVER unit. Flows from 2D HX cells can only be assigned to ISIS RIVER units.
Message Type
ERROR
Description
2D HX cell has been assigned to an ISIS non-RIVER unit. Only ISIS RIVER units or INTERPOLATE units may be connected to a 2D HX boundary in a linked ISIS-TUFLOW model.
Suggestions
Check the node type within the ISIS .dat file and remove connection (CN) lines within the 2d_bc layer at any non-RIVER/INTERPOLATE units.