Difference between revisions of "TUFLOW Message 1253"
Jump to navigation
Jump to search
m |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc=Unused data in table links (<tt>Read GIS Table Links == </tt>). A unused link to tabular input has been found, tabular data can include cross-section profiles, cross-section hydraulic parameters, nodal surface areas or bridge loss coefficients. This can occur if | + | |message_desc=Unused data in table links (<tt>Read GIS Table Links == </tt>). A unused link to tabular input has been found, tabular data can include cross-section profiles, cross-section hydraulic parameters, nodal surface areas or bridge loss coefficients. |
− | |suggestions=Check if the 1d_ta object | + | This can occur if: |
+ | * A cross-section with three or more vertices isn't snapped to a 1D network (1d_nwk) node | ||
+ | * A cross-section with two vertices does not intersect 1D network (1d_nwk) line | ||
+ | * A channel in the 1D network has both end and mid cross sections | ||
+ | * Two or more cross-sections exist in the same location | ||
+ | |suggestions= | ||
+ | * Check if the 1d_ta object is linked to the 1D network (either snapped for a 1d_ta object with 3 or more vertices or just intersecting if the 1d_ta object has only 2 vertices) | ||
+ | * Check if the 1D network channel has both mid- and end- cross-sections. If both mid- and end- sections exist, TUFLOW will ignore the end-cross-sections in favour of the mid-cross-sections (Refer to section 4.6.4 of the TUFLOW 2010 Manual) | ||
+ | * Check if cross-sections are both in the same location | ||
|discussion_page=* [[Talk:TUFLOW Message 1253|Discuss Message 1253]] | |discussion_page=* [[Talk:TUFLOW Message 1253|Discuss Message 1253]] | ||
|link3='' | |link3='' |
Revision as of 16:57, 12 March 2015
TUFLOW Message
WARNING 1253 - Unused 1d_ta line with attributes: ",a,",
Alternate Message
NA
Message Type
WARNING
Description
Unused data in table links (Read GIS Table Links == ). A unused link to tabular input has been found, tabular data can include cross-section profiles, cross-section hydraulic parameters, nodal surface areas or bridge loss coefficients.
This can occur if:
- A cross-section with three or more vertices isn't snapped to a 1D network (1d_nwk) node
- A cross-section with two vertices does not intersect 1D network (1d_nwk) line
- A channel in the 1D network has both end and mid cross sections
- Two or more cross-sections exist in the same location
Suggestions
- Check if the 1d_ta object is linked to the 1D network (either snapped for a 1d_ta object with 3 or more vertices or just intersecting if the 1d_ta object has only 2 vertices)
- Check if the 1D network channel has both mid- and end- cross-sections. If both mid- and end- sections exist, TUFLOW will ignore the end-cross-sections in favour of the mid-cross-sections (Refer to section 4.6.4 of the TUFLOW 2010 Manual)
- Check if cross-sections are both in the same location
Up |
---|
1xxx Messages |