|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain. | |message_desc=Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain. | ||
− | |suggestions= | + | |suggestions=Ensure that there is a CN object at each end of HX line connecting HX line to 1D node. |
|discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]] | |discussion_page=* [[Talk:TUFLOW Message 2061|Discuss Message 2061]] | ||
|link3='' | |link3='' |
Revision as of 15:22, 11 February 2011
TUFLOW Message
ERROR 2061 - Could not find a CN connection snapped to the end of HX line.
Alternate Message
NA
Message Type
ERROR
Description
Could not find a connection (CN object) snapped to the end of the 1D/2D interface (HX) line. Check that any connection object is snapped; add a connection to the end of the 1D/2D interface; or edit the 1D/2D interface line. 1D/2D interface lines based on the HX type must have as a minimum a connection at each of its ends, otherwise it is not clear how to transfer the water level gradient from the 1D domain.
Suggestions
Ensure that there is a CN object at each end of HX line connecting HX line to 1D node.