Difference between revisions of "TUFLOW Message 1522"

From Tuflow
Jump to navigation Jump to search
Line 1: Line 1:
 
{{TUFLOW_Message
 
{{TUFLOW_Message
 
|tuflow_message=ERROR 1522 - Unrecognised or unsupported operating control variable in line below, or invalid line
 
|tuflow_message=ERROR 1522 - Unrecognised or unsupported operating control variable in line below, or invalid line
#:Operating Control Line = <variable name> == <dHUD / dH12>
+
#:Operating Control Line = <variable name> == <dHUD or dH12>
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=When applying the Engelhund loss approach for manholes (see Section 4.5.2 of the 2010 TUFLOW manual), if an incoming culvert enters above the obvert of the highest outlet, the culvert is not included in the manhole loss calculations.  If there is only 1 incoming pipe with the invert above the obvert of the outlet culvert, the incoming culvert is ignored and with no inlet culvert to the node a manhole is not possible.  See also point 48(b) in the [http://www.tuflow.com/Download/TUFLOW/Releases/2012-05/Doc/TUFLOW%20Release%20Notes.2011-09%20and%202012-05.pdf release notes].
+
|message_desc=This error is a bug that will occur if you try to use the operating control variables "dHUD" or "dH12" using the 2013-12-AD or earlier build of TUFLOW.   
|suggestions=Review the inverts on the culverts.  A point object in a "1d_mh" layer can be used to set the loss approach at each manhole.
+
See also point 94 in the [http://www.tuflow.com/Download/TUFLOW/Releases/2013-12/Doc/TUFLOW%20Release%20Notes.2013-12.pdf release notes].
 +
|suggestions=Upgrade the build to 2013-12-AE
 
|discussion_page=* [[Talk:TUFLOW Message 1522|Discuss Message 1522]]
 
|discussion_page=* [[Talk:TUFLOW Message 1522|Discuss Message 1522]]
 
|link3=''
 
|link3=''

Revision as of 01:13, 19 June 2015

TUFLOW Message
ERROR 1522 - Unrecognised or unsupported operating control variable in line below, or invalid line

  1. Operating Control Line = <variable name> == <dHUD or dH12>

Alternate Message
NA

Message Type
ERROR

Description
This error is a bug that will occur if you try to use the operating control variables "dHUD" or "dH12" using the 2013-12-AD or earlier build of TUFLOW. See also point 94 in the release notes.

Suggestions
Upgrade the build to 2013-12-AE


Up
Go-up.png 1xxx Messages