Difference between revisions of "TUFLOW Message 2030"

From Tuflow
Jump to navigation Jump to search
Line 4: Line 4:
 
|type=[[ERROR]]
 
|type=[[ERROR]]
 
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
 
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
|suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries.  
+
|suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries. Refer to this forum post for more information: http://www.tuflow.com/forum/index.php?/topic/1533-error-2030-code-boundaries-and-pipe-outflows/
 
|discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]]
 
|discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]]
 
|link3=''
 
|link3=''

Revision as of 17:28, 27 August 2015

TUFLOW Message
ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary.

Alternate Message
NA

Message Type
ERROR

Description
Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).

Suggestions
Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries. Refer to this forum post for more information: http://www.tuflow.com/forum/index.php?/topic/1533-error-2030-code-boundaries-and-pipe-outflows/


Up
Go-up.png 2xxx Messages