|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary). | |message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary). | ||
− | |suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries. | + | |suggestions=Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries. Refer to this forum post for more information: http://www.tuflow.com/forum/index.php?/topic/1533-error-2030-code-boundaries-and-pipe-outflows/ |
|discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]] | |discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]] | ||
|link3='' | |link3='' |
Revision as of 17:28, 27 August 2015
TUFLOW Message
ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary.
Alternate Message
NA
Message Type
ERROR
Description
Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
Suggestions
Separate incompatible boundary types, for example a single 2D cell cannot be both a water level boundary and a flow boundary. The bcc_check layer is useful identifying cells acting as boundaries. Refer to this forum post for more information: http://www.tuflow.com/forum/index.php?/topic/1533-error-2030-code-boundaries-and-pipe-outflows/