TUFLOW Message 0500: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with "{{TUFLOW_Message |tuflow_message=WARNING 0500 - Reporting Location ID <reporting location ID> is common to more than one set of points and lines. |alt_msg=NA |type=WARNING..." |
No edit summary |
||
| Line 5: | Line 5: | ||
|message_desc=The same reporting location has been used on more than one point or line object. |
|message_desc=The same reporting location has been used on more than one point or line object. |
||
|suggestions=The same ID can be used on a reporting location line (flows) and point (water levels), however, these should be unique for each location. I.e. only one point and one line should have the same ID. |
|suggestions=The same ID can be used on a reporting location line (flows) and point (water levels), however, these should be unique for each location. I.e. only one point and one line should have the same ID. |
||
|discussion_page=* [[Talk:TUFLOW Message 0500|Discuss Message 0500]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_0439|Message 0439]] |
|prelink=[[TUFLOW_Message_0439|Message 0439]] |
||
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] |
|uplink=[[0xxx_TUFLOW_Messages|0xxx Messages]] |
||
Revision as of 15:20, 1 July 2022
TUFLOW Message
WARNING 0500 - Reporting Location ID <reporting location ID> is common to more than one set of points and lines.
Alternate Message
NA
Message Type
WARNING
Description
The same reporting location has been used on more than one point or line object.
Suggestions
The same ID can be used on a reporting location line (flows) and point (water levels), however, these should be unique for each location. I.e. only one point and one line should have the same ID.