TUFLOW Message 1031: Difference between revisions
No edit summary |
No edit summary |
||
Line 10: | Line 10: | ||
If the water level lines have only 2 vertices (no nodes on the lines, only a start and an end), then the line must go from 2d_bc to 2d_bc and '''cross''' the 1D network.<br> |
If the water level lines have only 2 vertices (no nodes on the lines, only a start and an end), then the line must go from 2d_bc to 2d_bc and '''cross''' the 1D network.<br> |
||
If the water level line have 3 or more vertices, then the line must go from 2d_bc to 2d_bc and '''snap''' to the 1D network. <br> |
If the water level line have 3 or more vertices, then the line must go from 2d_bc to 2d_bc and '''snap''' to the 1D network. <br> |
||
Should you need further information on configuring water level lines, refer to [http://wiki.tuflow.com/index.php?title=Tutorial_Module04#Review_the_Results Tutorial Model 4] |
Should you need further information on configuring water level lines, refer to <u>[http://wiki.tuflow.com/index.php?title=Tutorial_Module04#Review_the_Results Tutorial Model 4]</u> |
||
|discussion_page=* [[Talk:TUFLOW Message 1031|Discuss Message 1031]] |
|||
|link3='' |
|||
|link4='' |
|||
|prelink=[[TUFLOW_Message_1030|Message 1030]] |
|prelink=[[TUFLOW_Message_1030|Message 1030]] |
||
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
|uplink=[[1xxx_TUFLOW_Messages|1xxx Messages]] |
Revision as of 15:54, 1 July 2022
TUFLOW Message
ERROR 1031 - End of a WLL cannot snap to 1D node
Alternate Message
ERROR 1031 - End of a WLL cannot snap to a 1D channel
Message Type
ERROR
Description
This error indicates that there is a configuration problem with the 1d_wll and 1d_nwk layers
Suggestions
Load the messages, 1d_wll, 1d_nwk and 2d_bc layers into your GIS package. Using the messages layer, locate the area where the error occurs.
Check that the water level lines are configured correctly.
Remember:
Water level lines should go left to right looking downstream.
If the water level lines have only 2 vertices (no nodes on the lines, only a start and an end), then the line must go from 2d_bc to 2d_bc and cross the 1D network.
If the water level line have 3 or more vertices, then the line must go from 2d_bc to 2d_bc and snap to the 1D network.
Should you need further information on configuring water level lines, refer to Tutorial Model 4
Up |
---|
![]() |