TUFLOW Message 1353: Difference between revisions
No edit summary |
No edit summary |
||
| Line 4: | Line 4: | ||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).<br> |
|message_desc=If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).<br> |
||
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel. |
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.<br> |
||
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel. |
|||
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified. |
|suggestions=Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.<br> |
||
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel. |
|||
|discussion_page=* [[Talk:TUFLOW Message 1353|Discuss Message 1353]] |
|discussion_page=* [[Talk:TUFLOW Message 1353|Discuss Message 1353]] |
||
|link3='' |
|link3='' |
||
Revision as of 07:47, 11 May 2016
TUFLOW Message
ERROR 1353 - No NA data for Node <Node ID>
Alternate Message
ERROR 1353 - No CS data for Chan <Chan ID>
Message Type
ERROR
Description
If the message is "No NA data for Node" TUFLOW has encountered a 1D Node with no storage allocation. This typically occurs if the 'UCS' (use channel storage) attribute in a 1D network layer is set to 'F' (false).
If the message is "No CS data for Chan" no cross-sectional information has been provided for channel.
This error can also occur if you have a pit or node object, which is not correctly snapped to a channel.
Suggestions
Set the 'UCS' attribute to 'T' in the 1D network layer or manually assign storage via a "NA" table. For missing CS data, ensure that a cross-section has been correctly specified.
If this error occurs at a node or pit location, ensure that this is correctly snapped to a channel.
| Up |
|---|