TUFLOW Message 2107: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 3: Line 3:
|alt_msg=NA
|alt_msg=NA
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=Must use "2D Domain" commands to specify multiple 2D domains.
|message_desc=Must use "2D Domain" commands to specify multiple 2D domains. The mandatory .tcf commands that occur within a 2D domain block are:<br>
BC Control File <br>
Geometry Control File <br>
Timestep <br>
<br>
Optional commands that can be used are: <br>
Cell Wet/Dry Depth<br>
Cell Side Wet/Dry Depth<br>
Set IWL<br>
Read MI FC<br>
Read MI GLO<br>
Read MI IWL<br>
Read MID IWL<br>
Read MI LP<br>
Read MI PO<br>
Instability Water Level <br>

|suggestions=????
|suggestions=????
|discussion_page=* [[Talk:TUFLOW Message 2107|Discuss Message 2107]]
|discussion_page=* [[Talk:TUFLOW Message 2107|Discuss Message 2107]]

Revision as of 16:53, 13 October 2010

TUFLOW Message
ERROR 2107 - Command below must occur within a Start/End 2D Domain block.

Alternate Message
NA

Message Type
ERROR

Description
Must use "2D Domain" commands to specify multiple 2D domains. The mandatory .tcf commands that occur within a 2D domain block are:
BC Control File
Geometry Control File
Timestep

Optional commands that can be used are:
Cell Wet/Dry Depth
Cell Side Wet/Dry Depth
Set IWL
Read MI FC
Read MI GLO
Read MI IWL
Read MID IWL
Read MI LP
Read MI PO
Instability Water Level

Suggestions
????


Up
2xxx Messages