Difference between revisions of "TUFLOW Message 1005"
Jump to navigation
Jump to search
Chris Huxley (talk | contribs) |
|||
Line 4: | Line 4: | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=1D boundary condition (1d_bc) object is not snapped to a 1D node. | |message_desc=1D boundary condition (1d_bc) object is not snapped to a 1D node. | ||
− | |suggestions=Check snapping and location of 1d_bc object to ensure it is at a valid 1D node. | + | |suggestions=Check snapping and location of 1d_bc object to ensure it is at a valid 1D node (1d_nwk). |
|discussion_page=* [[Talk:TUFLOW Message 1005|Discuss (click to make suggestions about this page)]] | |discussion_page=* [[Talk:TUFLOW Message 1005|Discuss (click to make suggestions about this page)]] | ||
|link3='' | |link3='' |
Revision as of 13:30, 22 August 2016
TUFLOW Message
ERROR 1005 - Failed to find a node snapped to boundary condition with name ",a,
Alternate Message
NA
Message Type
ERROR
Description
1D boundary condition (1d_bc) object is not snapped to a 1D node.
Suggestions
Check snapping and location of 1d_bc object to ensure it is at a valid 1D node (1d_nwk).
Up |
---|
1xxx Messages |