|message_desc=????
+
|message_desc=A skew angle can be used to adjust the cross-section properties for XZ and CS/HW data according to the skew angle.  Useful where the cross-section line is surveyed oblique to the flow direction.  The skew angle is zero degrees in the direction of flow and 90 degrees if surveyed a right angles(!) to the direction of flow.  For example, a value of 45 adjusts the horizontal dimensions by dividing by the √2.
 
|suggestions=????
 
|suggestions=????
 
|discussion_page=* [[Talk:TUFLOW Message 1052|Discuss Message 1052]]
 
|discussion_page=* [[Talk:TUFLOW Message 1052|Discuss Message 1052]]

Revision as of 14:24, 31 January 2011

TUFLOW Message
WARNING 1052 - Skew angle of ",a," exceeds limit of 89.9 degrees. Reduced to 89.9.

Alternate Message
NA

Message Type
WARNING

Description
A skew angle can be used to adjust the cross-section properties for XZ and CS/HW data according to the skew angle. Useful where the cross-section line is surveyed oblique to the flow direction. The skew angle is zero degrees in the direction of flow and 90 degrees if surveyed a right angles(!) to the direction of flow. For example, a value of 45 adjusts the horizontal dimensions by dividing by the √2.