Difference between revisions of "TUFLOW Message 1052"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=WARNING 1052 - Skew angle of ",a," exceeds limit of 89.9 degrees. Reduced to 89.9. |alt_msg=NA |type=WARNING |message_desc=???? |suggestions...') |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[WARNING]] | |type=[[WARNING]] | ||
− | |message_desc= | + | |message_desc=A skew angle can be used to adjust the cross-section properties for XZ and CS/HW data according to the skew angle. Useful where the cross-section line is surveyed oblique to the flow direction. The skew angle is zero degrees in the direction of flow and 90 degrees if surveyed a right angles(!) to the direction of flow. For example, a value of 45 adjusts the horizontal dimensions by dividing by the √2. |
|suggestions=???? | |suggestions=???? | ||
|discussion_page=* [[Talk:TUFLOW Message 1052|Discuss Message 1052]] | |discussion_page=* [[Talk:TUFLOW Message 1052|Discuss Message 1052]] |
Revision as of 14:24, 31 January 2011
TUFLOW Message
WARNING 1052 - Skew angle of ",a," exceeds limit of 89.9 degrees. Reduced to 89.9.
Alternate Message
NA
Message Type
WARNING
Description
A skew angle can be used to adjust the cross-section properties for XZ and CS/HW data according to the skew angle. Useful where the cross-section line is surveyed oblique to the flow direction. The skew angle is zero degrees in the direction of flow and 90 degrees if surveyed a right angles(!) to the direction of flow. For example, a value of 45 adjusts the horizontal dimensions by dividing by the √2.
Suggestions
????
Up |
---|