Difference between revisions of "TUFLOW Message 1055"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1055 - Can only have one "M", "N" or "R" flag specified for cross-section ",a," in ",a, |alt_msg=NA |type=ERROR |message_desc=???? |sug...') |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=Can only have one of the following flags on a cross-section: <br> |
− | |suggestions= | + | “R” flag for relative resistance factor; <br> |
+ | “M” flag to use a material number; or <br> | ||
+ | “N” flag for a Manning’s n value. | ||
+ | |suggestions=Specify only one resistance flag for cross-section. | ||
|discussion_page=* [[Talk:TUFLOW Message 1055|Discuss Message 1055]] | |discussion_page=* [[Talk:TUFLOW Message 1055|Discuss Message 1055]] | ||
|link3='' | |link3='' |
Revision as of 14:33, 31 January 2011
TUFLOW Message
ERROR 1055 - Can only have one "M", "N" or "R" flag specified for cross-section ",a," in ",a,
Alternate Message
NA
Message Type
ERROR
Description
Can only have one of the following flags on a cross-section:
“R” flag for relative resistance factor;
“M” flag to use a material number; or
“N” flag for a Manning’s n value.
Suggestions
Specify only one resistance flag for cross-section.