Difference between revisions of "TUFLOW Message 1056"
Line 3: | Line 3: | ||
|alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a, | |alt_msg=ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a, | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc='''"E"''' and '''"T"''' are flow area flags (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. | + | |message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. <br> |
− | |suggestions= | + | <br> |
+ | '''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections. The ''''one'''' of the following should be specified:<br> | ||
+ | '''“F”''' for a multiplication factor; or<br> | ||
+ | '''“N”''' for a Manning’s n value. | ||
+ | |suggestions=Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags. | ||
|discussion_page=* [[Talk:TUFLOW Message 1056|Discuss Message 1056]] | |discussion_page=* [[Talk:TUFLOW Message 1056|Discuss Message 1056]] | ||
|link3='' | |link3='' |
Revision as of 15:34, 31 January 2011
TUFLOW Message
ERROR 1056 - Incompatible flags "E" and "T" specified for cross-section ",a," in ",a,
Alternate Message
ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
Message Type
ERROR
Description
"E" and "T" are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an “E” to use effective area or a “T” to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective.
"F" and "N" are vertical change in resistance for CS or HW type cross-sections. The 'one' of the following should be specified:
“F” for a multiplication factor; or
“N” for a Manning’s n value.
Suggestions
Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.