TUFLOW Message 1056: Difference between revisions
No edit summary |
No edit summary |
||
| Line 5: | Line 5: | ||
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. <br> |
|message_desc='''"E"''' and '''"T"''' are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an '''“E”''' to use effective area or a '''“T”''' to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective. <br> |
||
<br> |
<br> |
||
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections. |
'''"F"''' and '''"N"''' are vertical change in resistance for CS or HW type cross-sections. Only '''''one''''' of the following should be specified:<br> |
||
'''“F”''' for a multiplication factor; or<br> |
'''“F”''' for a multiplication factor; or<br> |
||
'''“N”''' for a Manning’s n value. |
'''“N”''' for a Manning’s n value. |
||
|suggestions=Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags. |
|suggestions=Specify only '''''one''''' of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags. |
||
|discussion_page=* [[Talk:TUFLOW Message 1056|Discuss Message 1056]] |
|discussion_page=* [[Talk:TUFLOW Message 1056|Discuss Message 1056]] |
||
|link3='' |
|link3='' |
||
Revision as of 15:35, 31 January 2011
TUFLOW Message
ERROR 1056 - Incompatible flags "E" and "T" specified for cross-section ",a," in ",a,
Alternate Message
ERROR 1056 - Incompatible flags "F" and "N" specified for CS data ",a," in ",a,
Message Type
ERROR
Description
"E" and "T" are flow area flags for XZ type cross-sections (see ecf command "Flow Area" in TUFLOW manual for more details). Specify an “E” to use effective area or a “T” to use total area when calculating the flow area. If neither is specified, the global value set using "Flow Area ==" is used, the default flow area method is effective.
"F" and "N" are vertical change in resistance for CS or HW type cross-sections. Only one of the following should be specified:
“F” for a multiplication factor; or
“N” for a Manning’s n value.
Suggestions
Specify only one of either an "E" or a "T" for flow area flags or "F" or "N" for vertically varying resistance flags.
| Up |
|---|