Difference between revisions of "TUFLOW Message 1068"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc=The data in the first column | + | |message_desc=The data in the first column of a cross-section is not unique or in ascending order. For a XZ (offset - elevation), the X data (offset) should be unique and in ascending order. The same applies to all cross-section types, e.g. for a HW (height - width) section, the height values should be increasing. |
|suggestions=Check data, remove duplicate values and sort by first column. | |suggestions=Check data, remove duplicate values and sort by first column. | ||
|discussion_page=* [[Talk:TUFLOW Message 1068|Discuss Message 1068]] | |discussion_page=* [[Talk:TUFLOW Message 1068|Discuss Message 1068]] |
Revision as of 15:52, 31 January 2011
TUFLOW Message
ERROR 1068 - First column values in cross-section data not in ascending order. Incorrect values are:
Alternate Message
NA
Message Type
ERROR
Description
The data in the first column of a cross-section is not unique or in ascending order. For a XZ (offset - elevation), the X data (offset) should be unique and in ascending order. The same applies to all cross-section types, e.g. for a HW (height - width) section, the height values should be increasing.
Suggestions
Check data, remove duplicate values and sort by first column.