TUFLOW Message 1123: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
Line 4: | Line 4: | ||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=Multiple cross-sections with the same priority have been found for channel. Mid channel cross-sections have higher priotity than end cross-sections and will prevail. But if multiple mid channel cross-sections are found TUFLOW will give Error 1123. |
|message_desc=Multiple cross-sections with the same priority have been found for channel. Mid channel cross-sections have higher priotity than end cross-sections and will prevail. But if multiple mid channel cross-sections are found TUFLOW will give Error 1123. |
||
|suggestions= |
|suggestions=Check channel and cross-section configuration, remove unwanted cross-section. |
||
|discussion_page=* [[Talk:TUFLOW Message 1123|Discuss Message 1123]] |
|discussion_page=* [[Talk:TUFLOW Message 1123|Discuss Message 1123]] |
||
|link3='' |
|link3='' |
Revision as of 09:40, 1 February 2011
TUFLOW Message
ERROR 1123 - More than one cross-section line of same priority for channel
Alternate Message
NA
Message Type
ERROR
Description
Multiple cross-sections with the same priority have been found for channel. Mid channel cross-sections have higher priotity than end cross-sections and will prevail. But if multiple mid channel cross-sections are found TUFLOW will give Error 1123.
Suggestions
Check channel and cross-section configuration, remove unwanted cross-section.
Up |
---|
![]() |