Created page with '{{TUFLOW_Message |tuflow_message=WARNING 1191 - Initial Water Level point is not snapped to a node. |alt_msg=NA |type=WARNING |message_desc=???? |suggestions=???? |discussion...' |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[WARNING]] |
|type=[[WARNING]] |
||
|message_desc=1d_iwl point is not snapped to a 1d node and is being ignored. The most likely cause of this is that the 1d_nwk has been modified and the 1d_iwl hasn't been updated. |
|||
|message_desc=???? |
|||
|suggestions=Check the location and snapping of the 1d_iwl object. |
|||
|suggestions=???? |
|||
|discussion_page=* [[Talk:TUFLOW Message 1191|Discuss Message 1191]] |
|discussion_page=* [[Talk:TUFLOW Message 1191|Discuss Message 1191]] |
||
|link3='' |
|link3='' |
||
Revision as of 15:22, 1 February 2011
TUFLOW Message
WARNING 1191 - Initial Water Level point is not snapped to a node.
Alternate Message
NA
Message Type
WARNING
Description
1d_iwl point is not snapped to a 1d node and is being ignored. The most likely cause of this is that the 1d_nwk has been modified and the 1d_iwl hasn't been updated.
Suggestions
Check the location and snapping of the 1d_iwl object.