Difference between revisions of "TUFLOW Message 1203"

From Tuflow
Jump to navigation Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |di...')
 
Line 3: Line 3:
 
|alt_msg=NA
 
|alt_msg=NA
 
|type=[[ERROR]]
 
|type=[[ERROR]]
|message_desc=????
+
|message_desc=An illegal Conn_2D attribute has been inputted on a 1d pit or node object.  The Conn_2D attribute is used to automatically link to the 2D.  Valid options are available:<br>
|suggestions=????
+
*SX<br>
 +
*SXL<br>
 +
*SXZ<br>
 +
*SXG<br>
 +
*SXS<br>
 +
For a detalied description of these options see Section 4.5.1.3 (Connecting Pits and Nodes to 2D Domains) and Table 4.14 (1D model Network (1d_nwk) Attribute Descriptions) of the TUFLOW manual (2010 version).
 +
|suggestions=Specify a valid attribute as per the list above.
 
|discussion_page=* [[Talk:TUFLOW Message 1203|Discuss Message 1203]]
 
|discussion_page=* [[Talk:TUFLOW Message 1203|Discuss Message 1203]]
 
|link3=''
 
|link3=''

Revision as of 15:28, 1 February 2011

TUFLOW Message
ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters.

Alternate Message
NA

Message Type
ERROR

Description
An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:

  • SX
  • SXL
  • SXZ
  • SXG
  • SXS

For a detalied description of these options see Section 4.5.1.3 (Connecting Pits and Nodes to 2D Domains) and Table 4.14 (1D model Network (1d_nwk) Attribute Descriptions) of the TUFLOW manual (2010 version).

Suggestions
Specify a valid attribute as per the list above.


Up
Go-up.png 1xxx Messages