TUFLOW Message 1203: Difference between revisions
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1203 - Invalid Conn_2D attribute at node. Cannot exceed 3 characters. |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |di...' |
No edit summary |
||
Line 3:
|alt_msg=NA
|type=[[ERROR]]
|message_desc=An illegal Conn_2D attribute has been inputted on a 1d pit or node object. The Conn_2D attribute is used to automatically link to the 2D. Valid options are available:<br>
*SX<br>
*SXL<br>
*SXZ<br>
*SXG<br>
*SXS<br>
For a detalied description of these options see Section 4.5.1.3 (Connecting Pits and Nodes to 2D Domains) and Table 4.14 (1D model Network (1d_nwk) Attribute Descriptions) of the TUFLOW manual (2010 version).
|suggestions=Specify a valid attribute as per the list above.
|discussion_page=* [[Talk:TUFLOW Message 1203|Discuss Message 1203]]
|link3=''
| |||