Difference between revisions of "TUFLOW Message 1257"
Jump to navigation
Jump to search
(Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1257 - No U/S and D/S bed levels specified for channel |alt_msg=NA |type=ERROR |message_desc=???? |suggestions=???? |discussion_page=*...') |
|||
Line 3: | Line 3: | ||
|alt_msg=NA | |alt_msg=NA | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
− | |message_desc= | + | |message_desc=Channel is missing upstream and downstream inverts. |
− | |suggestions= | + | |suggestions=Specify upstream and downstream inverts, via the 1D network channel, 1D network nodes snapped to end of channel or end cross-sections. |
|discussion_page=* [[Talk:TUFLOW Message 1257|Discuss Message 1257]] | |discussion_page=* [[Talk:TUFLOW Message 1257|Discuss Message 1257]] | ||
|link3='' | |link3='' |
Revision as of 09:22, 2 February 2011
TUFLOW Message
ERROR 1257 - No U/S and D/S bed levels specified for channel
Alternate Message
NA
Message Type
ERROR
Description
Channel is missing upstream and downstream inverts.
Suggestions
Specify upstream and downstream inverts, via the 1D network channel, 1D network nodes snapped to end of channel or end cross-sections.
Up |
---|
1xxx Messages |