TUFLOW Message 2014: Difference between revisions

From Tuflow
Jump to navigation Jump to search
Content deleted Content added
No edit summary
No edit summary
Line 4: Line 4:
|type=[[ERROR]]
|type=[[ERROR]]
|message_desc=No active 2D cells within Source over Area (SA) inflow polygon.
|message_desc=No active 2D cells within Source over Area (SA) inflow polygon.
|suggestions=Source-Area polygon in outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended.
|suggestions=????
|discussion_page=* [[Talk:TUFLOW Message 2014|Discuss Message 2014]]
|discussion_page=* [[Talk:TUFLOW Message 2014|Discuss Message 2014]]
|link3=''
|link3=''

Revision as of 12:30, 4 February 2011

TUFLOW Message
ERROR 2014 - No active cells within SA inflow polygon.

Alternate Message
NA

Message Type
ERROR

Description
No active 2D cells within Source over Area (SA) inflow polygon.

Suggestions
Source-Area polygon in outside of active model code. Check SA polygon is in the correct location, active model area (2D code) may need to be extended.


Up
2xxx Messages