Difference between revisions of "TUFLOW Message 2030"
Jump to navigation
Jump to search
Line 4: | Line 4: | ||
|type=[[ERROR]] | |type=[[ERROR]] | ||
|message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary). | |message_desc=Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary). | ||
− | |suggestions= | + | |suggestions=Seperate incompatible boundary types, for example a single 2D cell cannot be both a water level boudary and a flow boundary. |
|discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]] | |discussion_page=* [[Talk:TUFLOW Message 2030|Discuss Message 2030]] | ||
|link3='' | |link3='' |
Revision as of 16:49, 6 February 2011
TUFLOW Message
ERROR 2030 - Trying to apply a HT or HS boundary to a 2D cell already assigned a link or a HQ, Q or S boundary.
Alternate Message
NA
Message Type
ERROR
Description
Trying to apply a water level boundary (eg. HT or HS) to a 2D cell already assigned a link or incompatible boundary (ie. a HQ, Q or S boundary).
Suggestions
Seperate incompatible boundary types, for example a single 2D cell cannot be both a water level boudary and a flow boundary.
Up |
---|
2xxx Messages |