TUFLOW Message 1041: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 1041 - Culvert branch splits downstream of channel ",a," at Node ",a,". Could not interpolate invert. |alt_msg=ERROR 1041 - Culvert branch...' |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=ERROR 1041 - Culvert branch splits upstream of channel ",a," at Node ",a,". Could not interpolate invert. |
|alt_msg=ERROR 1041 - Culvert branch splits upstream of channel ",a," at Node ",a,". Could not interpolate invert. |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=Multiple upstream or downstream channel, unable to interpolate inverts. |
|||
|message_desc=???? |
|||
|suggestions=A useful tip at a junction of 1D channels is to use a connector (Channel_Type of “X”) for connecting a side tributary or pipe into the main flowpath. TUFLOW will then be able to interpolate inverts. Specify inverts on culvert object. |
|||
|suggestions=???? |
|||
|discussion_page=* [[Talk:TUFLOW Message 1041|Discuss Message 1041]] |
|discussion_page=* [[Talk:TUFLOW Message 1041|Discuss Message 1041]] |
||
|link3='' |
|link3='' |
||
Revision as of 17:26, 6 February 2011
TUFLOW Message
ERROR 1041 - Culvert branch splits downstream of channel ",a," at Node ",a,". Could not interpolate invert.
Alternate Message
ERROR 1041 - Culvert branch splits upstream of channel ",a," at Node ",a,". Could not interpolate invert.
Message Type
ERROR
Description
Multiple upstream or downstream channel, unable to interpolate inverts.
Suggestions
A useful tip at a junction of 1D channels is to use a connector (Channel_Type of “X”) for connecting a side tributary or pipe into the main flowpath. TUFLOW will then be able to interpolate inverts. Specify inverts on culvert object.
| Up |
|---|