TUFLOW Message 0116: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
Created page with '{{TUFLOW_Message |tuflow_message=ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0. |alt_msg=NA |type=ERROR |message_desc=????...' |
No edit summary |
||
| Line 3: | Line 3: | ||
|alt_msg=NA |
|alt_msg=NA |
||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m<sup>3</sup>/s is generated, and mass is created! |
|||
|message_desc=???? |
|||
|suggestions= |
|suggestions=Ensure first values in inlet curve are 0,0 |
||
|discussion_page=* [[Talk:TUFLOW Message 0116|Discuss Message 0116]] |
|discussion_page=* [[Talk:TUFLOW Message 0116|Discuss Message 0116]] |
||
|link3='' |
|link3='' |
||
Revision as of 19:10, 6 February 2011
TUFLOW Message
ERROR 0116 - First pair of values for pit inlet depth-flow curve for Inlet Type ",a," are not 0,0.
Alternate Message
NA
Message Type
ERROR
Description
First data pair for pit inlet curve (depth-flow) are not 0,0. The first values must be 0 (at depth 0) and 0 (flow is zero). Anything else is invalid, for example (0,0.1) would mean that at depth of zero a flow of 0.1 m3/s is generated, and mass is created!
Suggestions
Ensure first values in inlet curve are 0,0
| Up |
|---|