TUFLOW Message 2062: Difference between revisions
Jump to navigation
Jump to search
Content deleted Content added
No edit summary |
No edit summary |
||
| Line 4: | Line 4: | ||
|type=[[ERROR]] |
|type=[[ERROR]] |
||
|message_desc=Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object. |
|message_desc=Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object. |
||
|suggestions=SC line should only be used with SH boundary object. For SX and HX connections use CN objects. |
|||
|suggestions=???? |
|||
|discussion_page=* [[Talk:TUFLOW Message 2062|Discuss Message 2062]] |
|discussion_page=* [[Talk:TUFLOW Message 2062|Discuss Message 2062]] |
||
|link3='' |
|link3='' |
||
Revision as of 15:23, 11 February 2011
TUFLOW Message
ERROR 2062 - SC connection cannot connect to a HX line.
Alternate Message
NA
Message Type
ERROR
Description
Source conection (SC) cannot snap to a 1D/2D interface (HX) line. Source connections can only be connected to a Source versus Water Level (SH) boundary object.
Suggestions
SC line should only be used with SH boundary object. For SX and HX connections use CN objects.
| Up |
|---|