TUFLOW Message 2063: Difference between revisions
		
		
		
		Jump to navigation
		Jump to search
		
Content deleted Content added
| No edit summary | No edit summary | ||
| Line 4: | Line 4: | ||
| |type=[[ERROR]] | |type=[[ERROR]] | ||
| |message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0).  As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0). | |message_desc=Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0).  As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0). | ||
| |suggestions=If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used. | |||
| |suggestions=???? | |||
| |discussion_page=* [[Talk:TUFLOW Message 2063|Discuss Message 2063]] | |discussion_page=* [[Talk:TUFLOW Message 2063|Discuss Message 2063]] | ||
| |link3='' | |link3='' | ||
Revision as of 15:29, 11 February 2011
TUFLOW Message 
ERROR 2063 - Single CN connection to 1D Node must have a weighting factor (f) of 1.0.
Alternate Message 
NA
Message Type 
ERROR
Description 
Single connection (CN) to 1D Node must have a weighting factor (f attribute in 2d_bc layer) of one (1.0).  As of Build 2004-07-AC, a zero weighting factor is interpreted as a value of one (1.0).
Suggestions 
If using a single CN connection to a 1D node, ensure weighting factor (f) of 1.0 is used.
| Up | 
|---|
|  2xxx Messages |