Difference between revisions of "TUFLOW Message 2085"
Line 6: | Line 6: | ||
<font color="green"><tt>Bed Resistance Cell Sides == INTERROGATE</tt></font> is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the <font color="green"><tt>Read MID</tt></font> commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n. The two approaches are therefore incompatible. | <font color="green"><tt>Bed Resistance Cell Sides == INTERROGATE</tt></font> is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the <font color="green"><tt>Read MID</tt></font> commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n. The two approaches are therefore incompatible. | ||
− | |suggestions=Specify an interpolation method for cell sides (<font color="green"><tt>Bed Resistance Cell Sides == </tt></font>) if using <font color="green"><tt>Read MID</tt></font> commands to define roughness. Or use GIS inputs (<font color="green"><tt>Read GIS MAT | + | |suggestions=Specify an interpolation method for cell sides (<font color="green"><tt>Bed Resistance Cell Sides == </tt></font>) if using <font color="green"><tt>Read MID</tt></font> commands to define roughness. Or use GIS inputs (<font color="green"><tt>Read GIS MAT or FRIC == )</tt></font> with <font color="green"><tt>Bed Resistance Cell Sides == INTERROGATE</tt></font>. |
|discussion_page=* [[Talk:TUFLOW Message 2085|Discuss Message 2085]] | |discussion_page=* [[Talk:TUFLOW Message 2085|Discuss Message 2085]] | ||
|link3='' | |link3='' |
Revision as of 09:31, 15 February 2011
TUFLOW Message
ERROR 2085 - Read MID Mat or Read MID CnM cannot be used with Bed Resistance Cell Sides == INTERROGATE
Alternate Message
ERROR 2085 - Read MID Grid command cannot be used with Bed Resistance Cell Sides == INTERROGATE
Message Type
ERROR
Description
Read MID Mat, Read MID CnM or Read MID Grid .tgc commands cannot be used with Bed Resistance Cell Sides == INTERROGATE .tcf command. Specify Bed Resistance Cell Sides == AVERAGE n or Bed Resistance Cell Sides == AVERAGE M or Bed Resistance Cell Sides == MAXIMUM n in the .tcf file.
Bed Resistance Cell Sides == INTERROGATE is the default in the TUFLOW (as of TUFLOW Build 2007-07-AA), applies the exact value from the material polygons at each cell side. With the Read MID commands a value is inputted for each cell and value at cell side calculated using either average n, average M (1/n) or maximum n. The two approaches are therefore incompatible.
Suggestions
Specify an interpolation method for cell sides (Bed Resistance Cell Sides == ) if using Read MID commands to define roughness. Or use GIS inputs (Read GIS MAT or FRIC == ) with Bed Resistance Cell Sides == INTERROGATE.
Up |
---|
2xxx Messages |