MIKE Flood to TUFLOW: Difference between revisions

Content deleted Content added
Line 258:
 
The 1D run settings can be obtained from the .sim11 file. However it is recommended that appropriate run settings for TUFLOW be applied and direct copying from MIKE is not necessary.
 
===TUFLOW Commands===
 
The following commands can now written into the ECF to specify the Run Settings:
 
<font color='green'><tt>! Set 1D Run Settings</tt></font><br>
<font color='blue'><tt>Timestep</tt></font> <font color='red'><tt>==</tt></font> <tt>''<1D Timestep Interval in Seconds>''</tt><br>
<font color='blue'><tt>Output Interval (s)</tt></font> <font color='red'><tt>==</tt></font> <tt>''<1D Output Interval in Seconds>''</tt><br><br>
 
=Creating a TUFLOW Control File from MIKE21=